知識社群
登入
中文(台灣)
English(US)
Q&A
線上人數:
265
MODERN RADIOTHERAPY AND THERAPEUTIC RADIOLOGICAL PHYSICS
相簿輪播 - Welcome Address
社群功能
Home page
Documents
(15)
Calendar
Photo Album
(4)
文件分類
[
總覽
]
Sri Lanka WS
(15)
Vietnam WS
社群資訊
訪客: 70967
文章: 15
討論: 0
公告: 2
容量: 剩餘
1.4 GB
(1.9 GB)
閱讀權限: 開放
分類:
醫療保健 / 醫學新知
版主: tcc
副版主: 無
位置:
MODERN RADIOTHERAPY AND THERAPEUTIC RADIOLOGICAL PHYSICS
>
Documents
>
Sri Lanka WS
Brachytherapy LDR & HDR
(39:15)
Tweet
by tcc, 2011-04-21 16:37, 人氣(6773)
嵌入
|
cc Media
|
轉檔資訊
更清晰的畫質或聲音,請點選(限 IE)
標題
1.
Brachytherapy: LDR and HDR
2.
Brachytherapy
3.
Brachytherapy Isotopes
4.
Cesium-137 sourcesT1/2 = 30 y; Avg. gamma = 662 keV
5.
Iridium-192 sourcesT1/2 = 73.8 d; Avg. gamma = 380 keV
6.
Iodine-125 sourcesT1/2 = 60 d; Avg. gamma = 28 keV
7.
Palladium 103 sources T1/2 = 27d; Avg. gamma = 28 keV
8.
Cesium-131 sources T1/2 = 9.7d; Avg. gamma = 30.4 keV
9.
Radiological Physics Center
10.
Remote Afterloading
11.
Brachytherapy Treatment Sites
12.
Gynecological Brachytherapy
13.
Gynecological Brachytherapy – treatment planning
14.
Gynecological Brachytherapy – Manchester System
15.
Gynecological Brachytherapy – ICRU 38 recommendations
16.
Gynecological Brachytherapy – alternative applicators
17.
Gynecological Brachytherapy – alternative applicators
18.
Gynecological Brachytherapy – vaginal cancer
19.
Gynecological Brachytherapy – vaginal cancer
20.
Prostate Brachytherapy - LDR
21.
Prostate brachytherapy - LDR
22.
Prostate Brachytherapy - LDR
23.
Prostate brachytherapy - LDR
24.
Prostate Brachytherapy - LDR
25.
Prostate Brachytherapy - LDR
26.
Prostate LDR Isotopes
27.
Prostate Brachytherapy - HDR
28.
Current Research: Robotic Prostate Brachytherapy
29.
Robotic Prostate Brachytherapy
30.
Breast Brachytherapy
31.
Breast Brachytherapy -Indications
32.
Accelerated Partial Breast Irradiation: RTOG 0413 Protocol
33.
Target Identification
34.
Breast Brachytherapy -Indications
35.
Robotic Prostate Brachytherapy
36.
Breast Brachytherapy
37.
Accelerated Partial Breast Irradiation: RTOG 0413 Protocol
38.
Implant technique – planning for multicatheter brachytherapy
39.
RTOG 0413 Protocol Dose Uniformity Requirements
40.
Implant technique
41.
Treatment Planning
42.
Multicatheter implant - catheters color coded; skin marker over implant center
43.
3D reconstruction – skin dose
44.
Multicatheter HDR implant
45.
MammoSite System -Balloon is inflated with liquid inside surgical cavity -HDR source used to irradiate cavity walls to 1 cm-Balloons in various sizes, spherical and ellipsoidal
46.
Multicatheter HDR implant
47.
MammoSite System -Balloon is inflated with liquid inside surgical cavity -HDR source used to irradiate cavity walls to 1 cm-Balloons in various sizes, spherical and ellipsoidal
48.
MammoSite treatment
49.
Other cavity insertion systems
50.
Axxent (Xoft) Electronic Brachytherapy System: 3 Main Components
51.
Comparative dosimetry Ir192 vs. Xoft
52.
External Beam Partial Breast Irradiation, 4-field setup
53.
Summary
54.
External Beam Partial Breast Irradiation, 4-field setup
55.
Summary
... [more]
© 2010 FormosaSoft Corp.
http://www.powercam.com.tw
service@powercam.com.tw
All rights reserved.